Order Flags at Theodora's Flag Shop
A B C
D E F
G H I
J K L
M N O
P Q R
S T U
V W X
Y Z ?
PreviousNextSearchContentsONETLink to this SiteAbout

Spanish Simplified Chinese French German Russian Hindi Arabic Portuguese
CODE: 827.585-010Buy the DOT: Download
TITLE(s): FOAM CHARGER (svc. ind. mach.)

Tends equipment that blows foam insulation into cooler and refrigerator doors and cabinet walls, using portable foam gun: Connects foam pump and nitrogen pressure tank to resin and catalyst barrels. Turns valve to regulate nitrogen pressure at specified level. Connects hose from freon tank to gun and adjusts freon pressure. Opens gun valve and conducts foam test to ensure proper mixture of ingredients. Inserts nozzle of gun into compartment openings and blows specified amounts of foam insulation into doors and cabinet walls. Inserts plugs into openings to seal filled compartment. Regulates overhead electric heaters to maintain constant room temperature. Records number and type of units filled on daily production record. Cleans equipment and work area. May prepare units to receive insulation.
GOE: 06.04.36 STRENGTH: M GED: R2 M2 L2 SVP: 3 DLU: 77
ONET CROSSWALK: 92974 Packaging and Filling Machine Operators and Tenders

Previous Next Contents ONET About


CODE: 827.585-010 Buy the DOT: Download
TITLE(s): FOAM CHARGER (svc. ind. mach.)

Tends equipment that blows foam insulation into cooler and refrigerator doors and cabinet walls, using portable foam gun: Connects foam pump and nitrogen pressure tank to resin and catalyst barrels. Turns valve to regulate nitrogen pressure at specified level. Connects hose from freon tank to gun and adjusts freon pressure. Opens gun valve and conducts foam test to ensure proper mixture of ingredients. Inserts nozzle of gun into compartment openings and blows specified amounts of foam insulation into doors and cabinet walls. Inserts plugs into openings to seal filled compartment. Regulates overhead electric heaters to maintain constant room temperature. Records number and type of units filled on daily production record. Cleans equipment and work area. May prepare units to receive insulation.
GOE: 06.04.36 STRENGTH: M GED: R2 M2 L2 SVP: 3 DLU: 77
ONET CROSSWALK: 92974 Packaging and Filling Machine Operators and Tenders


© 1995 - 2015 Photius Coutsoukis and Information Technology Associates (All Rights Reserved). Revised 26-May-03