Order Flags at Theodora's Flag Shop
A B C
D E F
G H I
J K L
M N O
P Q R
S T U
V W X
Y Z ?
PreviousNextSearchContentsONETLink to this SiteAbout

Spanish Simplified Chinese French German Russian Hindi Arabic Portuguese
CODE: 827.584-014Buy the DOT: Download
TITLE(s): GAS-LEAK TESTER (svc. ind. mach.)

Performs one or more of following tasks to test assembled and charged refrigeration units for refrigerant leaks: Adjusts controls to set balance and range of electronic leak tester. Moves nozzle of tester along refrigerant lines, condenser, and compressor and listens for buzzer indicating presence of gas. Narrows range of tester and probes area to pinpoint exact location of leak. Turns valve of gas tester to adjust flow of gas to copper flame-ring and ignites gas. Moves suction hose, joined to flame-ring, along surfaces of refrigeration unit and observes flame for change in color denoting presence of leaking refrigerant gas. Wraps wet litmus paper around joints of refrigeration unit and observes paper for color change indicating refrigerant leak. Marks number of defective part or joint on inspection tag, according to blueprint numbering chart, and attaches tag to unit. Records number and location of leaks on inspection chart.
GOE: 06.03.02 STRENGTH: L GED: R2 M1 L1 SVP: 2 DLU: 77
ONET CROSSWALK: 83005A Production Inspectors, Testers, Graders, Sorters, Samplers, Weighers

Previous Next Contents ONET About


CODE: 827.584-014 Buy the DOT: Download
TITLE(s): GAS-LEAK TESTER (svc. ind. mach.)

Performs one or more of following tasks to test assembled and charged refrigeration units for refrigerant leaks: Adjusts controls to set balance and range of electronic leak tester. Moves nozzle of tester along refrigerant lines, condenser, and compressor and listens for buzzer indicating presence of gas. Narrows range of tester and probes area to pinpoint exact location of leak. Turns valve of gas tester to adjust flow of gas to copper flame-ring and ignites gas. Moves suction hose, joined to flame-ring, along surfaces of refrigeration unit and observes flame for change in color denoting presence of leaking refrigerant gas. Wraps wet litmus paper around joints of refrigeration unit and observes paper for color change indicating refrigerant leak. Marks number of defective part or joint on inspection tag, according to blueprint numbering chart, and attaches tag to unit. Records number and location of leaks on inspection chart.
GOE: 06.03.02 STRENGTH: L GED: R2 M1 L1 SVP: 2 DLU: 77
ONET CROSSWALK: 83005A Production Inspectors, Testers, Graders, Sorters, Samplers, Weighers


© 1995 - 2015 Photius Coutsoukis and Information Technology Associates (All Rights Reserved). Revised 26-May-03